Modbus Monitor Advanced icon

Modbus Monitor Advanced

★★★★★
★★★★★
(0.00/5)

Varies with device$0.992 years ago

Download Modbus Monitor Advanced APK latest version Free for Android

Version Varies with device
Update
Size Varies with device
Developer Hubble Software
Category Apps, Tools
Package Name com.Bhavan.Galex
OS Varies with device

Modbus Monitor Advanced APPLICATION description

Modbus Client/Poll Server/Simulator, TCP/IP, Bluetooth/BLE, RS232 Serial Port
This Modbus App has three Apps in one. Android Modbus Master/Client/Poll, Slave/Server/Simulator, and Sensors Server. This simple to use utility is simple has many advanced features unmatched even by PC-based standards.

> Choose 4 Interfaces: (1) Bluetooth SPP & BLE, (2) Ethernet, (3) Wi-Fi, (4) RS232/485 USB Serial ports (USB OTG capable devices)

> Choose from 8 Modbus Protocols: Modbus TCP, Enron/Daniels TCP, Modbus RTU over TCP, Modbus UDP, Modbus RTU over UDP, Modbus TCP Slave/Server, Modbus RTU, Modbus Serial ASCII

> Explore Sensor Server: Remotely monitor mobile device's sensors using Modbus Protocol (sensors such as Gyro, GPS, *Cell Phone Tower, etc.) remotely with built-in Modbus Sensor Server

> Log data to ThinkSpeak platform: Graphically log and view data on ThinkSpeak cloud.

> Log data Google Sheets: Use phone sensor (or any polled data) and log values straight into your private Google Spreadsheet in the cloud!!! The same Google Sheet can be used to centrally log values from different mobile devices into one Google Sheet (one file per device or all devices).

> Easy to use Import/Export: Import in CSV format. Export data to CSV format every second, minute, or hour. Export configuration data via email or log to ThinkSpeak or Google Sheets Cloud platforms

> Modbus Functions: FC1, FC2, FC3, FC4, FC5, FC6, FC15, FC16, Write Auto Pick

> Simple 6 digit Input Modbus Address input

> Push to write pre-set value

> Convert Modbus Integer Values to Text (Coded Message or Status Converter)

> Data Conversion: Unsigned, Signed, Hex, Binary, Long, Double, Float, String, BCD formats, Unix Epoch Time, PLC Scaling (Bipolar/Unipolar Analog ADC value conversion)

> Pro Tuning Options: Interval, Inter-Packet Delay, Link-Timeout, Actual RX/TX Counts

> Bluetooth Requirement
1. Your device must have Bluetooth Radio that supports SPP profile (RFCOMM Secure or Insecure)
2. See "ModbusMonitor.com" or email [email protected] for help
3. See below for hardware requirements

> USB-to-Serial Port Requirement, USB OTG Serial Ports>> RS232/422/RS485
Your device must meet all of the THREE requirements.

1. Your device must be Android version 3.2 or newer
2. Your device must support USB Host or OTG interface
3. Your USB-to-Serial Port dongle must contain one of following chipsets: >FTDI [FT230X, FT231X, FT234XD, FT232R, or FT232H], Prolific [PL2303HXD, PL2303EA, or PL2303RA], SiLab [CP210x], QinHeng CH34x
4. RS485: Tested with "no echo" setting turned ON.

More: www.modbusmonitor/guide/serialport

> Feedback
www.ModbusMonitor.com contains an online form in the "Feeback" section for those interested in providing constructive feedback or feature requests.

> Help
- www.modbusmonitor.com/help
- email: [email protected]
↓ Read more
Modbus Monitor Advanced screen 1 Modbus Monitor Advanced screen 2 Modbus Monitor Advanced screen 3 Modbus Monitor Advanced screen 4 Modbus Monitor Advanced screen 5 Modbus Monitor Advanced screen 6 Modbus Monitor Advanced screen 7 Modbus Monitor Advanced screen 8